DSTS-5A/2C©
EDI's Chirp SONAR Test Set

[ Home] [ Chirp Depth Sounder Test Set] [ Computer Controlled Depth Sounder Test Set]
[ Low Frequency Universal Transducer Test Set] [ Universal Transducer Test Set] [ Multi Sensor Transducer Test Set ]
[ Computer Controlled Transducer Test Set ] [ Loran-C Signal Generator ] [ Downloads]


The DSTS-5A/2C is a computer controlled depth sounder tester designed for testing chirp sonar over the frequency range of 1.5 kHz to 500 kHz. The transmitted pulse from the sonar is digitized and stored in memory. After the selected depth delay, the stored echo pulse is returned to the sonar with the same frequency spectrum and length as the pulse received from the sonar.

DSTS-5A/2C Chirp SONAR Test Set

[Specifications]


SPECIFICATIONS:

Parameter Range Resolution Accuracy
Sample Rate
40 MHz
n/a
± .01%
Input frequency 1.5 to 500 kHz1 25 ns ± .02% ±20 Hz 2
Input width 1100 cycles max
0.1 uS ± .02% ±2 cycles
Input period 10 to 9999 mS 1 mS ± .02% ±1 mS
Input voltage 50 to 2500 Vp-p 2 Vp-p ± 10% Vp-p ±5%3
Min input level 504 Vp-p n/a
n/a
Output frequency 1.5 to 500 kHz 25 ns
± .01%
Output width Tracks input pulse
0.1 uS ± .02%
Echo depth 1 to 100,000 ft/fm/mt 0.1 unit ± .01%
Output level 2 uV to 50,000 uV 0.3 dB
± 1.0 dB
Vprop ft, fm 4800 to 5000 f/s 1 f/s
± .01%
Vprop mtrs 1460 to 1530 m/s 1 m/s
± .01%
Depth jitter: Less than 50 nSec maximum at 1 second depth delay.
Baud rate: 9600, 8 bits, no parity, no handshake
Power requirements: 9 Vdc @ 200 mA
Size and Weight: 6" W by 7"D by 3.5"H. Shipping Wt. 2.1 Lbs.

Notes:
1 - Usable to > 550 Khz with reduced amplitude accuracy.
2 - Specified for constant frequency pulse with width greater than 100 uS.
3 - Measured at 200KHz, 400Vp-p with a 325 uSec pulse width.
4 - At 50 Khz. Approximately 120 Vp-p at 500 kHz.

Please E-Mail edisales@bbginc.com or telephone (757) 366-9211 (within the USA) for more information on EDI's product design services.

Click here to email your questions or comments to EDI.


[ Home ] [ Options for Depth Sounder Test Set ] [ Depth Sounder Test Set ]
[ Multi-Sensor Transducer Test Set ]
[ Downloads ]


EDI Electronic Devices, Inc.
1708 South Park Court, Chesapeake, VA 23320. Phone (757) 366-9211

Cat DSTS-5A01/98


Copyright 1998-2012, Electronic Devices, Inc.
1708 South Park Court
Chesapeake, Virginia 23328
(757) 366-9211 USA